Fire and emergency preparedness in restaurants

A useful restaurant emergency plan turns foreseeable hazards into clear arrangements for every shift. An extinguisher or a document on a shelf cannot establish readiness on its own. Usable exits, customer guidance, available trained personnel and resolved defects belong in the same management process.
Scope: general guidance for restaurants and cafés employing staff in Türkiye. It does not replace a workplace risk assessment, approved emergency plan, technical fire design, training or competent specialist review. Staffing and equipment requirements must reflect the actual premises.
1. Keep employer responsibility clear
Türkiye’s Ministry of Labour and Social Security identifies risk assessment and emergency preparedness as employer duties. Article 5 of the Workplace Emergencies Regulation expressly preserves the employer’s obligations when employees receive special assignments. Giving a shift lead a follow-up task does not transfer legal responsibility.
Confirm the hazard classification, headcount, shifts, shared areas and applicable technical requirements with your occupational safety specialist. Do not infer classification from the restaurant sign or copy one branch’s plan into another.
2. Map the whole premises
Review the kitchen, storage, dining room, terrace and delivery area together. Bring cooking equipment, grease accumulation, electrical and gas installations, cleaning chemicals, packaging storage and neighbouring premises into the risk assessment. Fire, earthquake and medical emergencies may require different arrangements.
Use competent authorised providers for maintenance and technical checks. Do not derive extinguisher types, quantities, detector positions or maintenance intervals from this article. İstanbul Fire Brigade’s guidance relates protection equipment to building characteristics; actual suitability needs on-site assessment.
3. Make a shift coordination card
Establish statutory teams and training under the applicable rules. The card below is only an operational example, not a substitute for those appointments. Match trained personnel and any deputies to actual shifts, including leave and staff departures.
- Coordination: who knows the current plan and assignments and liaises with building management?
- Notification: who contacts 112 from safety, with the exact address, entrance information and callback number?
- Guidance: who communicates the safe evacuation arrangements to customers, including people needing mobility or communication support?
- Assembly: who accounts for staff and tells responders about missing people and their last known location? Uncertain customer numbers must remain identified as uncertain.
These roles do not extend anyone’s training or authority. General awareness is different from specialist emergency training and first-aider competence. Connect induction to the first-week training programme and continuity to shift planning.
4. During an incident: people and 112 first
Teach staff the workplace warning, evacuation and assembly arrangements beforehand. For fire or immediate danger to life, call 112 from a safe position. Give the exact address, incident location, known hazards and reliable information about anyone possibly inside; follow the call handler’s directions. Waiting for managerial approval must not delay notification.
Do not ask untrained staff to fight a fire, intervene in gas installations or search inside. Any intervention belongs only to designated trained people within their plan, competence and safety limits. Do not attempt a hazardous or smoke-blocked route. If safe evacuation is impossible, tell 112 your location and follow instructions. Do not re-enter for a missing person, possessions or cash. Resume access or service only after the competent responders confirm safety.
5. Example: an evening shift gap
An opening check in a two-storey restaurant finds packaging narrowing a planned exit route and the listed trained person on leave. These are real preparedness gaps, not a drill. The employer arranges correction and suitable shift coverage; the follow-up owner verifies the route on site, updates assignments and explains the change. A serious unresolved hazard cannot simply be deferred. Competent people must assess safe use of the affected area and operation.
6. Preparedness checklist
For every item record ready / gap / assessment needed, evidence, follow-up owner, target date and closure verification. This is an internal management tool, not a compliance certificate.
- Branch-specific scenarios, layout and current plan version checked?
- Planned escape routes and exits usable, with understandable guidance?
- Assembly point, staff accounting and reporting of uncertainty clear?
- Customers, visitors and people needing assistance included?
- Trained personnel and any deputies actually covered on every shift?
- Exact address and entrance instructions readily available for 112?
- Equipment, installation and maintenance defects reviewed by competent people?
- New and temporary staff briefings recorded?
- Latest drill findings corrected and verified?
- Changes to equipment, layout, premises or surroundings assessed for plan revision?
7. Turn drills into completed actions
Articles 13–15 treat drills, plan renewal and training separately. In non-mining workplaces such as restaurants, drills must take place at least annually. Maximum plan renewal intervals vary by hazard classification, and changes creating new risks can require earlier revision. Verify applicable requirements for the actual workplace rather than waiting for the next calendar date.
Record participants, communication problems and misunderstood areas; assign corrections and verify completion. Link training and maintenance evidence with inspection preparation. The Ministry’s emergency plan preparation guide is supporting guidance; a completed template alone does not prove safe conditions.
Sources and review date
Sources checked 29 October 2026. Displayed publication: 29 October 2026, not a legal commencement date. The regulation was first published on 18 June 2013; the official text used records amendments dated 1 October 2021. The Ministry guide states a 2024 update. Its cover contains an inconsistent Official Gazette issue reference; the regulation itself was used for article checks.